Passive Optical Splitter
Open Admin/Inventory and create new device of PON type and SPLITTER model (you need to do this manually as splitter is a passive device).
Then attach meta attributes - splitter-role
(see below) and splitter-ports
(number of splitter ports).
In Interfacess tab create new virtual interface and connect it as uplink to source OLT device. If there are multiple splitters in the path, create as many as needed and connect them through virtual interfaces.
Splitter role
trunk
not for access (only to connect multiple splitters)
access-welded
no attributes, welded fibers
access
- subrack[1..24]
- cartridge[1..24]
- port[1..24]
access-pillar
- cartridge[1..50]
- port[1..24]
- riser[1..4]
- color[red blue green yellow purple white orange gray brown lightgreen cyan pink]
- stripes[no-stripe single-stripe double-stripe]
access-building
- riser[1..2]
- color[red blue green yellow purple white orange gray brown lightgreen cyan pink]
- stripes[no-stripe single-stripe double-stripe]
Last modified
4 years ago
Last modified on Sep 18, 2020, 8:16:56 AM
Note:
See TracWiki
for help on using the wiki.